Address
Shuangyu Road Leshang Pioneer Prak
Yueqing Bay Area Yueqing City Zhejiang Province 325600 China

Work Hours
Monday to Friday: 9AM - 7PM
Weekend: 10AM - 5PM

HLC-1XT01AAC(1P/25A/120VAC) Definite Purpose Contactor

$13.00

HLC-1XT01AAC(1P/25A/120VAC) Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 25A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

1000 in stock

Shipping Now

*Applicable and Description

1. Applicable Scope

HLC-1XT01AAC(1P/25A/120VAC) Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 25A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

2.Type and Meaning

 

HL

C

1X

T

01

AA

 C

Company Code

Contactor

Packing Y : Individual Box Pack    – : Factory Bulk Pack

Pole: One Pole with Shunt

Coil Voltage

Rating of current

Terminal

With Cover

*Product Explanation And Main Technical Parameter

Type

HLC-1XT01AAC(1P/25A/120VAC) Definite Purpose Contactor

Standard

IEC60947

UL508

Rating of Current

Ie 25A

FLA: 25A

Resistive Amps

Ith 35A

RES: 35A

Rating of Contacts Voltage

Ue 240/277V

240/277/480/600VAC

Rating of Insulation Voltage

Ui 660V

600V

Rating of Coil Voltage

Us 120V

Us: 120VAC 50/60Hz

Mechanical Life

1000,000 Cycle

1000,000 Cycle

Electricity life

100,000 Cycle

250,000 Cycle

Product Explanation

1.Product Description

HLC-1XT01AAC Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 240V OR 277v, Fixed Operating Current To 25A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control.

2 .The Regular Service Conditon And Installs The Condition 
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25 
b. The Installation Site Elevation Does Not Surpass 2000m 
c. The Air Pollution Rank Is 2 Levels 
d. Installs The Category Is Ii ; 
e. Installment Facing The Gradient Does Not Surpass ±5° 
f. Not Remarkable Undulation, Impact And Vibration Place.

3 .Main Technical Parameter 
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably 
Working, Its Drop Out Voltage In 20% ~ 70%Us 
b. Contactor Use Category: Ac-1Ac8a 
c. Contactor In With 0.4m Place, Its Noise Below 40db.

4 . Installing Specification And Install Size

a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°

b. Before The Use Should Inspect The Power Terminal And The Contactor 
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating 
The Breakdown, Behind Check Off May Electrify Tries . 

 

*Conforms To The Standard

Conforms To National Standard And International Standard

1 Conforms To UL508, IEC60947, GB14048Standard

2 Approved By UL,CUL,TUV,CE,CCC,Safe Certification and ISO9001 System Certification(SGS)

CCC Certificate Number:  2005010309156761

UL Files Number: E251539

*Ordering Request

In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order. 

Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc

If You Request As Follows: Nominal Current: 25A, Working Voltage: 240/277V,480V,600V, Pole Number: One Pole Without Shunt, Coil Control Voltage:120V, Wiring Way: Quick Connect, Load Current: Single-Phase Motor Controls Or Heating Load, Packing: 50/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-1XT01AAC

Lifts The Samples As Follows (Contains Derivation Type From This Model) 

Rating of Current

Ie

Pole

Rating of Coil Control Voltage 

Control Motor Power

24VAC

120VAC

208/240VAC

277VAC

380/480VAC

240VAC

25A

1.5P

HLC-1XQ01AAC

HLC-1XT01AAC

HLC-1XU01AAC

HLC-1XV01AAC

HLC-1XH01AAC

1.5Kw

HLC Series Definite Purpose Contactor
Weight 0.31 kg
Dimensions 9 × 5.5 × 7 cm

Reviews

There are no reviews yet.

Be the first to review “HLC-1XT01AAC(1P/25A/120VAC) Definite Purpose Contactor”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

You may also like…

en_USEnglish
Powered by TranslatePress