Champ d'applicationRelais haute puissance HLR6100-2ATUBCF-VAC208/240 2A is 2 pole, nominal current 25A attaches the post (T) primarily, the screw post (B), the printed wiring board uses the post (P) and so on. Is suitable in the compressor, the heater control, the motor, the power source control, the duplicator, the facsimile machine, the flare control, the microwave oven, electric appliances and equipment’s and so on packaging machine and food processing machinery single-phase load circuit’s control. This product has the volume to be small, the weight is light, the coil power loss is low, the contact load is big, anti-impact ability, characteristics and so on redundant reliability.
|
| Type et signification |
HL | R | 6100 | – | 2A | T | UB | CF | -VAC240 |
Hongli Electric | Relais | Taper | Packing Y :Individual Box Pack – : Factory Bulk Pack | Contact form 1A:SPNO 2A:DPNO | T:Quick-connect terminals P:PCB terminals B:Screw terminals | J:with test button UB: With bracket type | Isolation de classe F | tension de commande de la bobine:208/240VAC |
1. Explication du produit et principaux paramètres techniques
| ★ Tension d'isolement nominale Ui : 600 V |
| ★ Tension nominale des contacts Ue : 277 V CA |
| ★ Intensité nominale : Ie = 25 A (AC-8b), Ith = 30 A |
| ★ Durée de vie mécanique > 10 000 000 cycles |
| ★ Durée de vie électrique > 100 000 cycles |
| ★Plage de tension de fonctionnement de la bobine: 70% ~ 110%Us |
| ★ tension de fonctionnement de la bobine du produit Us=12,24,36,48,110/120,220/240VAC&VDC |
2.Conforme à la norme
Conforme aux normes nationales et internationales | 1. Conforme à UL508, IEC60947, GB14048 Standard. |
| 2.Approuvé par UL, RoHS et ISO9001 Certification du système (SGS). |
| Numéro de dossier UL : E251539 |
3.Demande de commande
Afin de garantir votre achat correct, veuillez lire attentivement les spécifications du produit avant de commander.
Relay Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc
If you request as follows: Nominal current: 25A, working voltage: 240/277V, pole number: 2 pole, coil control voltage:120VDC, wiring way: A group 1/4 ” fast attachment, load: The single-phase perception or the linear load, brings the test button, the insulation grade: CLASS F, packing: 120/each box (factory packing). Then you may the shaping be:HLR6100-2ATUBCF-VAC208/240