Address
Shuangyu Road Leshang Pioneer Prak
Yueqing Bay Area Yueqing City Zhejiang Province 325600 China

Work Hours
Monday to Friday: 9AM - 7PM
Weekend: 10AM - 5PM

HLC-4XT04CG(4P/40A/120V) DEFINITE PURPOSE CONTACTOR

$26.00

*Applicable and Description

1. Applicable Scope

HLC-4XT04CG(4P/40A/120V) Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 40A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

     2.Type and Meaning

 

HL C 4X

T

04 CG  
Hongli Electric Contactors

Packaging

Pole Form

Coil Voltage

Contact Rating

Termination

 
“Y” :Individual Box Pack 4X : 4Pole T:120VAC 04: FLA 40A CG: #14-4 Lug with dual QC  
“-” :Factory Bulk Pack 

*Product Explanation And Main Technical Parameter

Type

HLC-4XT04CG(4P/40A/120V) Definite Purpose Contactor

Standard IEC60947 UL508
Rating of Current Ie 40A FLA: 40A
     
Rating of Contacts Voltage Ue 240/277V 240/277/480/600VAC
Rating of Insulation Voltage Ui 660V 600V
Rating of Coil Voltage Us 120V  
Mechanical Life 1000,000 Cycle 1000,000 Cycle
Electricity life 100,000 Cycle 250,000 Cycle
Product Explanation

1.Product Description

HLC-4XT04CG(4P/40A/120V) Definite Purpose Contactor Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 600v, Fixed Operating Current To 40A Three-Phase Load Circuit Control,At Present, Widely Applies To The Three-Phase Mechanical Device Main Circuit As Well As The Three-Phase Air-Conditioner Compressor Control.

2 .The Regular Service Conditon And Installs The Condition 
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets 
Down The Limiting Value Is -25 
b. The Installation Site Elevation Does Not Surpass 2000m 
c. The Air Pollution Rank Is 2 Levels 
d. Installs The Category Is Ii ; 
e. Installment Facing The Gradient Does Not Surpass ±5° 
f. Not Remarkable Undulation, Impact And Vibration Place.

3 .Main Technical Parameter 
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably 
Working, Its Drop Out Voltage In 20% ~ 70%Us 
b. Contactor Use Category: Ac-1Ac8a 
c. Contactor In With 0.4m Place, Its Noise Below 40db.

4 . Installing Specification And Install Size

a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°

b. Before The Use Should Inspect The Power Terminal And The Contactor 
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating 
The Breakdown, Behind Check Off May Electrify Tries . 

 

 

*Conforms To The Standard

Conforms To National Standard And International Standard

 

1 Conforms To UL508, IEC60947, GB14048Standard
2 Approved By UL,CUL,TUV,CE,CCC,Safe Certification and ISO9001 System Certification(SGS)

CCC Certificate Number:  2005010309156761

UL Files Number: E251539

*Ordering Request

In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order. 

Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc

 
If You Request As Follows: Nominal Current: 20A, Working Voltage: 240/277V,480V,600V, Pole Number: Four Pole Without Shunt, Coil Control Voltage:24V, Wiring Way: Quick Connect, Load Current: Three-Phase Motor Controls Or Heating Load, Packing: 25/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-4XT04CG

Lifts The Samples As Follows (Contains Derivation Type From This Model) 

Rating of Current

Ie

Pole Rating of Coil Control Voltage  Control Motor Power
24VAC 120VAC 208/240VAC 277VAC 380/480VAC 240VAC
40A

4P

HLC-4XQ04CG HLC-4XT04CG HLC-4XU04CG HLC-4XV04CG HLC-4XH04CG 7.5Kw
Weight 0.6 kg

Reviews

There are no reviews yet.

Be the first to review “HLC-4XT04CG(4P/40A/120V) DEFINITE PURPOSE CONTACTOR”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

en_USEnglish
Powered by TranslatePress